contact download


Catalog
Download

DP gauge digital pressure gauge DP-340 / DP-340B / DP-340BA

DP-340 / DP-340B / DP-340BA

Multifunction Digital Pressure Gauge DP-340 series

Excellent overpressure resistant Digital Pressure Gauge available in a wide variety of ranges from Micro-differential pressure (500 Pa) to High pressure (50 MPa).

Edge & Function



Features

●Available in a wide variety of ranges from Micro-differential pressure of 500 Pa to High pressure of 50 MPa.

●Internal or external sensor with excellent overpressure resistance

●Switchable display rate according to the application

●Easy replacement by current DP-320 and DP-330

●All the models come with Traceability and Calibration Certificates.


Spec



Common Spec. (DP-340 / 340B / 340BA)

Micro pressure (Differential pressure) Gauge pressure
Accuracy ±0.3% of F.S. ±1 digit ±0.25% of F.S. ±1 digit
Temperature characteristic (Zero) ±0.03% of F.S./℃
Temperature characteristics (Span) ±0.03% of F.S./℃
Pressure media Noncorrosive gases Noncorrosive gases and liquid compatible with SUS630
Transducer type Inductance type Capacitance type
Sensing element Beryllium copper SUS630
Allowable pressure Ranges 50 kPa or lower: 10 times of F.S Ranges 5 MPa or lower: 2 times of F.S
Ranges 100 kPa or higher: 5 times of F.S Ranges 10 MPa or higher: 1.5 times of F.S. Range
Response time (Step response) 300ms or lower/99% of F.S. 30ms or lower/99% of F.S.
Sensor Internal Volume HI: 8.3 mL  LO: 9.8 mL Approx. 3.5 mL

Individual Features (DP-340 / 340B / 340BA)

DP-340 DP-340B DP-340BA
Display Digits 33.5 digits
Display range: 000 to  1999
Selectable 3.5 digits/4.5 digits
Display range: 000 to  1999 / 0000 to  19999
Decimal Point Fixed Can be set to any digit position
Sampling Time Can be toggled between 250 ms and 50 ms
Analog output 0.5, 1, 2 VDC  Voltage output corresponding to the readings
Option: 5, 10 VDC
BCD output Option Open collector  Max. load: 50 VDC, 35 mA Open collector  Max. load: 55 VDC, 20 mA
Sensor Zero adjustment Zero adjustment
RS-232C serial communication 1200, 9600, 19200 bps
Digital filter Running average Selectable from Heavy (20 times), Medium (7 times) and Light (3 times) filtering
LED brightness adjustment 7 levels
Keyboard locking False operation prevention
Upper and Lower Limit Settings Comparator Upper limit (HI) and Lower limit (LO) Upper limits (HH, HI) and Lower limits (LO, LL)
User span 0.001 to 9.999 times
Channel 10 channels selectable
Display hold Only for BCD option
External operation only
Display hold Display hold/Peak hold
/Bottom hold
Auto-zero Only for BCD option
External operation only
Auto-zero button
Power source 24 VDC, 0.2 A (Comes with 100 to 240 VAC power adapter) 24 VDC, 0.3A (Comes with 100 to 240 VAC power adapter)
Operating temperature 5~40℃
Sensor separate configuration Option:   Standard cable 3 m,  Drip-proof available
CE conformity × Only for internal sensor models
Compound pressure (Pressure/Vacuum) Available for all the ranges of Micro pressure (Differential pressure) and Gauge pressure
Pressure inlet port Rc 1/8

Pressure range (DP-340 / 340B / 340BA)

Range code Pressure type Measurement range Display digit at F.S.
5PD Differential pressure 0 to 500Pa 500
1KD Differential pressure 0 to 1kPa 1.000
2KD Differential pressure 0 to 2kPa 1.999
5KD Differential pressure 0 to 5kPa 5.00
10KD Differential pressure 0 to 10kPa 10.00
20KD Differential pressure 0 to 20kPa 19.99
50KD Differential pressure 0 to 50kPa 50.0
100KD Differential pressure 0 to 100kPa 100.0
50KG Gauge pressure 0 to 50kPa 50.0
100KG Gauge pressure 0 to 100kPa 100.0
200KG Gauge pressure 0 to 200kPa 199.9
500KG Gauge pressure 0 to 500kPa 500
1MG Gauge pressure 0 to 1MPa 1.000
2MG Gauge pressure 0 to 2MPa 1.999
5MG Gauge pressure 0 to 5MPa 5.00
10MG Gauge pressure 0 to 10MPa 10.00
20MG Gauge pressure 0 to 20MPa 19.99
50MG Gauge pressure 0 to 50MPa 50.0
V1KD Vacuum differential pressure 0 to -1kPa -1.000
V2KD Vacuum differential pressure 0 to -2kPa -1.999
V5KD Vacuum differential pressure 0 to -5kPa -5.00
V10KD Vacuum differential pressure 0 to -10kPa -10.00
V20KD Vacuum differential pressure 0 to -20kPa -19.99
V50KD Vacuum differential pressure 0 to -50kPa -50.0
V100KD Vacuum differential pressure 0 to -100kPa -100
V50KG Vacuum gauge pressure 0 to -50kPa -50.0
V100KG Vacuum gauge pressure 0 to -100kPa -100

 

Classification



Model (DP-340 / 340B)

DP-340_形式

Category Symbol Contents
A Pressure range See the Range List
B Sensor Type N Equipped with a Pressure Sensor (Standard)
S1 External Pressure Sensor Configuration
S2 External Drip-proof Pressure Sensor Configuration
Sensor Cable Length

(Available only when S1 & S2 are selected)

L1 3m(Standard)
LX 1m to 10m
Other Options B (Only for DP-340) BCD Output
F1 Analog output F.S. 5 V
F2 Analog output F.S. 10 V
A Analog Current Output 1-20 mA
C Power Adapter (Standard) VG Power cord 100 VAC, 3 m
VH Power cord 240 VAC, 2 m
Comes with no Power Adapter VJ Comes with no Power Adapter
External 24 VDC is required.

Model (DP-340BA)

DP-340BA_形式

Category Symbol Contents
A Pressure range See the Range List
B Sensor Type N Equipped with a Pressure Sensor (Standard)
S1 External Pressure Sensor Configuration
S2 External Drip-proof Pressure Sensor Configuration
Sensor Cable Length

(Available only when S1 & S2 are selected)

L1 3 m (Standard)
LX 1 m to 10 m
Analog output F1 Analog output F.S. 5 V
F2 Analog output F.S. 10 V
A Analog Current Output 1-20 mA
Interface Q1 Input 5 V  (Standard 24 V)
C Power Adapter (Standard) VG Power cord 100 VAC, 3 m
VH Power cord 240 VAC, 2 m
No power Adapter VJ No power AdapterExternal 24 VDC is required.


Appearance



DP-340 External Appearance

DP-340B External Appearance

DP-340BA External Appearance