NL-S2 Series
There are Single to Triple valves and combinations for Normally Open and Normally Closed are selectable depending of the products the valve is used for.
※NL select valve cannot be controlled by Air Leak Tester.Separate PLC and Solenoid valve are required.
Operating pressure range | Medium and Low Pressure: 0 to 500 kPa Vacuum Pressure: 0 to -100 kPa |
---|---|
IN and OUT connection port | Rc1/4: (Same diameter for Come with a stop valve option) |
Pilot pressure port | Comes with a 4 mm Push-on fitting |
Orifice diameter | Ø5 |
Valve seat leak | 0.007 mL/min or less |
Pilot pressure | 400 to 700kPa Connected to 4 mm diameter Push-on fitting |
A | Number of Valves | 1 : Single | 2 :Dual | 3 : Triple |
---|---|---|---|---|
B | Specifications | 0 : Normally Open × 1 1 : Normally Closed × 1 |
0 : Normally Open × 2 1 : Normally Closed × 2 2 : Normally Open × 1、Normally Closed × 1 |
0 : Normally Open × 3 1 : Normally Closed × 3 |
C | Operating pressure range | M : Medium and Low Pressure, V : Vacuum Pressure | ||
D | Option | B : Comes with a Stop valve |