LS-R910
Test 1 location Test pressure 2 ranges
Test 3 locations Test pressure 2 ranges
The combination of test pressure ranges of 2 circuits (Port-A/Port-B) can be chosen from the support table below.
Of the combinations of various pressure ranges, choose two types that meet your demands from the table below.
Pressure is applied to the workpiece.
If you push the button above, it will be shifted to the following button for easy fine tuning of the pressure.
During setup, a large numeric keypad appears, and all types of settings can be adjusted using the simple screen display.
Regarding the convenient functions of the LS-R900 which are included in the LS-R910, please consult the LS-R900 page.
Link --> LS-R900 product information
DP sensor and display (standard) | Resolving power Display range Sensor range Excess pressure on sensors Display precision *1 |
0.1 Pa ±2500 Pa ±1000 Pa ±2000 Pa 5 MPa ±2.5% of rdg ±1Pa、However 50Pa following ± 2Pa |
---|---|---|
Test Pressure Sensor and Display | Display precision | ±1% of F.S. ±1 digit (linearity, hysteresis, reproducibility) |
Temperature properties | ±0.1% of F.S. / °C | |
Display units *2 | Test Pressure: | kPa, MPa (PSI, kg/cm2, bar, mbar, mmHg, cmHg, inHg) |
Leak volume | Pa, kPa, mL/s, mL/min, L/min, Pa・m3/s, E-3 Pa・m3/s, Pa/s, Pa/min, (mmH2O, inH2O, mmHg, in3/min, in3/d, , ft3/h) |
|
Leak volume display | 3 to 5 digits (floating point), sample rate: 10/second | |
Leak limit (standard) | ±999.9Pa or less | |
Number of Channels | 32ch(0~31) | |
Timer setting range | 999.9 seconds (resolving power: 0.1 second) | |
Power Source | AC100 to 240V±10%, 50/60Hz, 80VAmax Fuse (T2.5A 250V) Dielectric strength and resistance AC1400V 10 sec, DC500V 50MΩ Internal solenoid power supply: DC24V |
|
Test pressure source | Uses clean air.The original pressure must be sufficiently higher than the test pressure. | |
Pilot pressure source | Applies 400 to 700kPa of clean air. | |
CPU | ARM9 400MHz, DRAM 128MB | |
LCD/TP | 5.7 inch color LED 640 x 480 pixels (VGA) | |
Pipe connection diameter | Rc(PT) 1/4 test pressure supply, pilot air supply, workpiece piping, master piping | |
Ambient temperature | Operating temperature 5 to 45°C Storage temperature: -20 to 60°C Consult if using in a high temperature environment. |
|
Humidity | 80 %RH or less No dew condensation | |
Mass | Approx. 14kg (standard specifications) | |
Serial communications RS232C-based (D-sub9-pin) 2 port |
I/F fixed length output | Leak data and set values are outputted simultaneously |
ID/F fixed length output Standard settings |
Leak data and set values are outputted simultaneously | |
T/F fixed length output | Only leak data outputted | |
Other formats | ||
USB Port | Saving data | Saves decisions, leak values, correction values, test pressure, WK#, CH#, and time on inserted memory. (Automatic file creation every 24 hours) |
Set values storage | All channel settings, system settings, etc. | |
LAN Port | Intend to include FTP server function | |
Maintenance/calibration port | M10 x 1.5 (O-ring seal) | |
Electro-pneumatic regulator | Repeatability: ±0.5% of F.S. and belowTemperature properties: ±0.16% of F.S./°C | |
Control I/O connector, caps (2) for RS-232C, USB cover, test report, traceability documents, user manual | ||
Ambient properties (IEC 6101-1) | Overvoltage category II | Protection class I |
Peripherals | Master chamber, leak master, bypass unit, external exhaust valve, etc. |
*1 The display precision is that at the time of delivery.
The precision when inspecting and calibrating is ± 5% of rdg ±1Pa.
The precision of the DP display of the option, wide range is ± 5% of rdg ±0.01kPa.
*2 The unit ( ) is not fixed in the SI unit specifications.
NOTE: If using overseas, please use a power cord that conforms to the respective country’s norms and regulations.
① | Pneumatic Circuit | A1:Intelligent 1 Pneumatic Circuit, A2:Intelligent 2 Pneumatic Circuit, AS1:Intelligent 1 Pneumatic Circuit for small-volume workpieces. AS01:Micro-volume workpiece circuit, C:External pressure detection type |
|
---|---|---|---|
② | Pressure range (Port-A) |
Electro-pneumatic regulator | LR:10~95kPa、MR:50~800kPa、VR:-5~-75kPa |
Regulator | L02:5~20kPa、 L:10~100kPa、 M:50~800kPa、
H20:2.0MPa以下 *1、 H49:4.9MPa以下 *1 |
||
③ | Pressure range (Port-B) |
Electro-pneumatic regulator | LR:10~95kPa、MR:50~800kPa、VR:-5~-75kPa |
Regulator | L02:5~20kPa、 L:10~100kPa、 M:50~800kPa、V:-5~-100kPa | ||
④ | Options | J:Leak Master support, K05:ALC-05付0.5mL、 K1:ALC-1付1mL、 K4:ALC-4付4mL、 K10:ALC-10付10mL、 B:Bypass support (without regulator) *2、 B1:Bypass support (with regulator) *2、 D:DP sensor range ±10kPa |
|
⑤ | Power cable | VA:AC125V 3m accessory cable,、 VE:AC250V 2m accessory cable |
*1: A regulator is not included with H20, H49.
*2: B、B1 only support Port-B.